Another approach if you can still reach the P50 over IP:
Use a tftp server and download your actual config via SNMP if you know the RW community or this comminutiy has not been set.
set sysConfigTftpHostAddr to your tftp-server.
set sysConfigTftpFilename to a full qualified file which must exist and have rw- rights for everyone.
set sysConfigTftpCmd to 1 (do tsave).
If this works you should be able to read the passwords from the file.
Note: TFTP is not routable, tftp-server must be in the same segment as the P50.
Hope it helps....
Burkhard Weeber
viastore systems GmbH
P/O Box 300668
D-70446 Stuttgart
Email: B.Weeber@viastore.de
> -----Original Message-----
> From: owner-ascend-users@max.bungi.com
> [mailto:owner-ascend-users@max.bungi.com]On Behalf Of Henning Pfeiffer
> Sent: Monday, August 23, 1999 3:54 PM
> To: ascend-users@bungi.com
> Subject: Re: (ASCEND) P50 & forgotten password?
>
>
> "Bluett, Mike" wrote:
> >
> > Hi all,
> >
> > Sometime ago on this list it was mentioned that either P6
> or P9 was the jumper to short out to clear the flash config
> in the case of a forgotten password.
> >
> > Has anyone got the exact info/procedure as my initial
> attempts have failed.
> >
> > Thanks very much
> >
> > =======================================================
> > Mike Bluett <mbluett@bc.net>
> > BCNet Network Management Center
> > Vancouver, B.C.
>
> Hi Mike!
>
> As far as I can remember you have to short out jumper P9. But there is
> more than meets the eye. For the following procedure you need two
> releases of the Pipe-50 firmware which are quite distant in version
> number. Connect to your Pipe via serial port using minicom or
> something
> similiar (e.g. Windows Hyperterminal) with a rate of 57600
> bps. Set your
> Pipe to receive files (you have to enter "df" on the debug line). A
> sequence of "CK" states the Pipe to be ready. Then upload the old
> release first (ZMODEM), reset the Pipe (turn off/turn on
> power), upload
> the new release (ZMODEM), turn off again, remove the jumper and have
> fun. Ah, one last thing, your configuration is certainly gone
> for good.
>
> BEWARE! Ascend does not recommend this approach and does not guarantee
> that your Pipe will still be functioning after these extreme measures
> ...
>
> Regards!
>
> --
> +-Gigabell AG Germany--+-CERT/ACCESS/DNS/MAIL----+
> | fon +49 69 17084 700 | technik@gigabell.net |
> | fax +49 69 17084 701 | H.Pfeiffer@gigabell.net |
> +----------------------+--------Henning Pfeiffer-+
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to
> ascend-users-request@bungi.com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>