> Another approach if you can still reach the P50 over IP:
> Use a tftp server and download your actual config via SNMP if you 
> know the RW community or this comminutiy has not been set.
> 
> set sysConfigTftpHostAddr to your tftp-server.
> set sysConfigTftpFilename to a full qualified file which must 
> exist and have rw- rights for everyone.
> set sysConfigTftpCmd to 1 (do tsave).
> 
> If this works you should be able to read the passwords from the file.
> 
> Note: TFTP is not routable, tftp-server must be in the same 
> segment as the P50.
At which point did TFTP become un-routable?
> 
> Hope it helps....
> 
> Burkhard Weeber
> viastore systems GmbH
> P/O Box 300668
> D-70446 Stuttgart
> Email: B.Weeber@viastore.de
> 
> > -----Original Message-----
> > From: owner-ascend-users@max.bungi.com
> > [mailto:owner-ascend-users@max.bungi.com]On Behalf Of Henning Pfeiffer
> > Sent: Monday, August 23, 1999 3:54 PM
> > To: ascend-users@bungi.com
> > Subject: Re: (ASCEND) P50 & forgotten password?
> > 
> > 
> > "Bluett, Mike" wrote:
> > > 
> > > Hi all,
> > > 
> > > Sometime ago on this list it was mentioned that either P6 
> > or P9 was the jumper to short out to clear the flash config 
> > in the case of a forgotten password.
> > > 
> > > Has anyone got the exact info/procedure as my initial 
> > attempts have failed.
> > > 
> > > Thanks very much
> > > 
> > > =======================================================
> > > Mike Bluett   <mbluett@bc.net>
> > > BCNet Network Management Center
> > > Vancouver, B.C.
> > 
> > Hi Mike!
> > 
> > As far as I can remember you have to short out jumper P9. But there is
> > more than meets the eye. For the following procedure you need two
> > releases of the Pipe-50 firmware which are quite distant in version
> > number. Connect to your Pipe via serial port using minicom or 
> > something
> > similiar (e.g. Windows Hyperterminal) with a rate of 57600 
> > bps. Set your
> > Pipe to receive files (you have to enter "df" on the debug line). A
> > sequence of "CK" states the Pipe to be ready. Then upload the old
> > release first (ZMODEM), reset the Pipe (turn off/turn on 
> > power), upload
> > the new release (ZMODEM), turn off again, remove the jumper and have
> > fun. Ah, one last thing, your configuration is certainly gone 
> > for good.
> > 
> > BEWARE! Ascend does not recommend this approach and does not guarantee
> > that your Pipe will still be functioning after these extreme measures
> > ...
> > 
> > Regards!
> > 
> > -- 
> > +-Gigabell AG Germany--+-CERT/ACCESS/DNS/MAIL----+
> > | fon +49 69 17084 700 | technik@gigabell.net    |
> > | fax +49 69 17084 701 | H.Pfeiffer@gigabell.net |
> > +----------------------+--------Henning Pfeiffer-+
> > ++ Ascend Users Mailing List ++
> > To unsubscribe:	send unsubscribe to 
> > ascend-users-request@bungi.com
> > To get FAQ'd:	<http://www.nealis.net/ascend/faq>
> > 
> 
> ++ Ascend Users Mailing List ++
> To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd:	<http://www.nealis.net/ascend/faq>
> 
> 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>