Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) P130 and T1



I have six P130's connected to T1 frame relay at both full T1 and sub rate
port speeds. No problems. The oldest have been in use since the P130 was
first available.

At 12:13 PM 1/25/98 -0800, Terrelle Shaw wrote:
>We have been using the P-130 on our T1 for over 2 years. the only gripe i
>have is sometimes when i telnet to the router, it causes a
>reboot. Pisses me off, cause with our telco, the line doesn't come back up
>for at least 3+ mins. Our telco has a cisco on the other end.
>Plus were bridging the p130 with another p-130 so i have to turn that
>connection profile off, so the line can come back up AT ALL, AND MOST of
>the time when this reboot happens it looses it default route so i have to
>completely remove the default route, put something in there.. reboot.. then
>change it back..( crazy huh?)
>But other than that.. i have no CRC errors or anything.. ( I just don't
>telnet into it often) Hehehehe.. but all these things might be because
>were running 4.6A.. will upgrade soon.. maybe it would clear that
>telnet rebooting problem and lost of default route problem..
>
>
>At 12:06 PM 1/25/98 -0600, Miles Lott wrote:
>>Well, that is the answer I didn't want to hear:)  Hopefully, there
>>are some successful installs out there?  I suppose we could try to
>>make a case for an exchange since we bought this through the ISP.
>>Or we could jump off to another service with the Cisco/ADC setup.
>>I can't see continuing with this if it will not be reliable at T1
>>speeds.
>>TTYL
>>
>>On Sun, 25 Jan 1998, Bob Roswell wrote:
>>
>>> We had  a customer using the P-130s on a T-1 Line. and switched to
>Cisco's. 
>>> The P-130 is much more cost effective particularly if you want and ISDN 
>>> backup....
>>> But the rock solid reliability is not there.  With the P-130's we 
>>> intermittently get a huge number of CRC errors.  Rebooting one or  the 
>>> other P-130's
>>> fixed the problem -- until it reappeared.  Since we went with Cisco
>Routers 
>>> and ADC Kentrox CSU's, we have had zero problems.
>>> Bob Roswell
>>> broswell@syssrc.com
>>> 
>>> ++ Ascend Users Mailing List ++
>>> To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
>>> To get FAQ'd:	<http://www.nealis.net/ascend/faq>
>>> 
>>
>>++ Ascend Users Mailing List ++
>>To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
>>To get FAQ'd:	<http://www.nealis.net/ascend/faq>
>>
>>
>
>++ Ascend Users Mailing List ++
>To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
>To get FAQ'd:	<http://www.nealis.net/ascend/faq>
>
>
++ Ascend Users Mailing List ++