Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Max 1800 with 5.0Ap16, Error Code #164
At 01:42 AM 1/24/98 +0900, Peter Chow wrote:
>We have a Max 1800 running 5.0Ap16, switch type=Japan, 4
>BRIs with 1 modem card for analog dialup, connected to
>a Cisco 2501 via a crossover cable.
>
>The Max 1800 would lose network connectivity after about
>30 minutes - 1 hour. We've replaced the tranceiver, cross
>over cable and even a different Max 1800 (one that works
>fine elsewhere). Power supply is on UPS. Also tried direct
>power from the wall outlet.
>
>When it crashes and we try to go to the terminal server
>mode, it comes up with an error message "#164". Does
>anyone know what this code means? I've been unable to
>find it in the manuals or on Ascend's web site.
From: Billie Alsup (A godlike creature in the engineering group ;)
"Terminal server not available"
he's trying to get into the terminal server (from the
LCD screen), and it is failing. possible reasons
include:
a. terminal server is disabled
ethernet->mod config->Tserv options...->TS enabled=no
b. there are too many terminal server sessions in use
c. we're low on memory and couldn't allocate the data structures
needed for a new terminal server
Kevin
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
Follow-Ups:
References: