Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Problem: MAX-1800, with more than 7 Connections
I've seen the exact same issue here, Usually a bounce of the box will
cause it to re-sync with the D Channel, I believe this was an issue
in the early 5.0 stream, Have you tried loading 5.0Ap38?
Jason Nealis
Director Internet Operations
Network Access
Erols Internet
On Thu, 8 Jan 1998, Bob Roswell wrote:
> I have two MAX-1800 which both exhibit the same problem
> I have 1 device connected to the serial lan, and 6 devices connected to
> the BRI's. Everything is stable.
> If I add a 7th BRI to either unit, the router works for a while, but then
> the router tells me that another BRI line is unavailable,
> (The status goes from D to a - or sometimes an M or even an X).
> Rebooting or toggling the BRI line sometimes solves the problem for a
> few hours.
> I am running Software +5.0Ap16+.
> Any suggestions
>
> broswell@syssrc.com
> (410) 771-5544 ext 336
> www.syssrc.com
>
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to ascend-users-request@bungi..com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
References: