(ASCEND) Re: ascend-users-digest V96 #747



There is a workaround. Use a dynamic or static IP other than the one 
the incoming call uses:

user	Password = "xxxxxxxxxx"
 User-Name = "blabla",
 Framed-Protocol = PPP,
 User-Service = Framed-User,
 Framed-Address = 192.162.1.1,
 Framed-Netmask = 255.255.255.248,
 Ascend-Idle-Limit = 60,
 Framed-Routing = None

userout	Password = "ascend", User-Service = Dialout-Framed-User
 Ascend-Require-Auth = Not-Require-Auth,
 Framed-Protocol = PPP,
 Ascend-Dial-Number = 012345678,
 Ascend-Data-Svc = Switched-64K,
 Ascend-Route-IP = Route-IP-Yes,
 Framed-Address = 255.255.255.254,
 Framed-Netmask = 255.255.255.255,
 Ascend-Expect-Callback = Expect-Callback-Yes, 
 Ascend-Base-Channel-Count = 1,
 Ascend-Minimum-Channels = 1,
 Ascend-Idle-Limit = 2,
 Framed-Routing = None

This avoids the lan security (which is caused by the Maxen routemgr 
due to duplicated routes).

Nevertheless, you might still need two B-channels on the remote side 
sometimes.

Torsten Droste

> Date:          Wed, 13 Aug 1997 11:13:07 -0700
> From:          owner-ascend-users-digest@max.bungi.com
> To:            ascend-users-digest@max.bungi.com
> Subject:       ascend-users-digest V96 #747
> Reply-to:      ascend-users@max.bungi.com

> From: Joerg Bauer <joerg@germany.net>
> Date: Wed, 13 Aug 1997 08:21:30 +0200
> Subject: Re: (ASCEND) Callback Problems
> 
> we have the same problem here with some MAX. As far as I know it has
> something to do with the Deutsche Telekom, our national phone provider.
> They said that they have the right to wait up to 40 sec to send the the
> information that the other side of the connection has terminated the
> call. So the other side calls back and the MAX sees 2 open connections
> to one destination -> LAN security error.
> This doesn=B4t happen in every location. German Telekom is using differen=
> t
> software in there Locations. In most cases it works.=20
> But never the less Ascend should be able to give us a workaround for
> this problem.
> 
> 

----------------------------------------------------------
Torsten Droste                      td@pop-stuttgart.net
Internet PoP Stuttgart IPF.NET      phone: +49 711 6574500
INC InterNet Connectivity GmbH      fax:   +49 711 6574501
Schenkendorfstr. 17                 70193 Stuttgart
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>