Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Re: ascend-users-digest V96 #747
- To: ascend-users@max.bungi.com
- Subject: (ASCEND) Re: ascend-users-digest V96 #747
- From: "Torsten Droste" <td@cd-ware.de>
- Date: Thu, 14 Aug 1997 10:46:40 +0100
- Comments: Authenticated sender is <td@inc-mail.cd-ware.de>
- In-reply-to: <199708131813.LAA29561@max.bungi.com>
- Organization: INC InterNet Connectivity GmbH
- Priority: normal
- Sender: owner-ascend-users@max.bungi.com
There is a workaround. Use a dynamic or static IP other than the one
the incoming call uses:
user Password = "xxxxxxxxxx"
User-Name = "blabla",
Framed-Protocol = PPP,
User-Service = Framed-User,
Framed-Address = 192.162.1.1,
Framed-Netmask = 255.255.255.248,
Ascend-Idle-Limit = 60,
Framed-Routing = None
userout Password = "ascend", User-Service = Dialout-Framed-User
Ascend-Require-Auth = Not-Require-Auth,
Framed-Protocol = PPP,
Ascend-Dial-Number = 012345678,
Ascend-Data-Svc = Switched-64K,
Ascend-Route-IP = Route-IP-Yes,
Framed-Address = 255.255.255.254,
Framed-Netmask = 255.255.255.255,
Ascend-Expect-Callback = Expect-Callback-Yes,
Ascend-Base-Channel-Count = 1,
Ascend-Minimum-Channels = 1,
Ascend-Idle-Limit = 2,
Framed-Routing = None
This avoids the lan security (which is caused by the Maxen routemgr
due to duplicated routes).
Nevertheless, you might still need two B-channels on the remote side
sometimes.
Torsten Droste
> Date: Wed, 13 Aug 1997 11:13:07 -0700
> From: owner-ascend-users-digest@max.bungi.com
> To: ascend-users-digest@max.bungi.com
> Subject: ascend-users-digest V96 #747
> Reply-to: ascend-users@max.bungi.com
> From: Joerg Bauer <joerg@germany.net>
> Date: Wed, 13 Aug 1997 08:21:30 +0200
> Subject: Re: (ASCEND) Callback Problems
>
> we have the same problem here with some MAX. As far as I know it has
> something to do with the Deutsche Telekom, our national phone provider.
> They said that they have the right to wait up to 40 sec to send the the
> information that the other side of the connection has terminated the
> call. So the other side calls back and the MAX sees 2 open connections
> to one destination -> LAN security error.
> This doesn=B4t happen in every location. German Telekom is using differen=
> t
> software in there Locations. In most cases it works.=20
> But never the less Ascend should be able to give us a workaround for
> this problem.
>
>
----------------------------------------------------------
Torsten Droste td@pop-stuttgart.net
Internet PoP Stuttgart IPF.NET phone: +49 711 6574500
INC InterNet Connectivity GmbH fax: +49 711 6574501
Schenkendorfstr. 17 70193 Stuttgart
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>