Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) telstra rsoft restart and max 7.0.3
There is an issue in early 7.0 release of MAX code, where the ISDN
signalling back to the exchange is slightly screwy.
I remember something being about the MAX not seeing the disconnect from the
exchange. Software Resets of the MAX did not fix it, but hardware resets
did, & so did removing the PRI cable, & re- inserting.
Ash
----- Original Message -----
From: <sysop@netlink.net.au>
To: <ascend-users@bungi.com>
Sent: Wednesday, 20 October 1999 08:49
Subject: (ASCEND) telstra rsoft restart and max 7.0.3
> Hi
> I have a problem with my max 6000 running 7.0.3 - all seems fine except
> with regard to Aust Telstra doing a soft reboot of my Onramp service. This
> happend last week due to the local exchange having an upgrade (9 hours off
> line) and again last night (1 hour off line) due to an exchange having a
> total restart. My max just sits there with the Alarm light on and trunk
> down on the telnet window.
>
> I suspect there is a prob with this version of the OS but as all else seem
> fine I dont wish to upgrade and brake other stuff.
>
> any sugestions / recom. appreciated.
> ken
>
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>