Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) Quiescenting PRIs



The US does not follow the ITU standards, generally
the ITU comes up with a flavor, then Bellcore/ANSI
releases theres.

For a channel to remain blocked, the host providing the
channel must provide the BLO every 4-5 minutes.  Lack of
this message with a good Level 2 on the circuit with D
Channel operational, an UBL will be sent to the receiving
CPE, which the TNT responds to with a BLA, thereby 
releasing the channel from blocking.

Simple fix would be to put a state on that circuit as being
blocked, and not respond with BLA, but with a RESET OUT OF
SERVICE message.

just my 2 cents.

shawn
slewis@xcom.net


On Fri, 23 Jan 1998, Matt Holdrege wrote:

> At 06:30 PM 1/23/98 -0500, Shawn Lewis wrote:
> >Q.931/SS7 Standards
> >
> >Please reference the "T" timers under 931/ISUP conversion
> >and standard default timers.
> 
> I know about ITU Q.931, but that has nothing to do with taking a channel
> out of service. What ANSI specs were you referring to?
> 
> Matt Holdrege		http://www.ascend.com	matt@ascend.com
> 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>