Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Max-4000 E1/T1



On Thu, Apr 16, 1998 at 06:28:04PM -0400, Jason Nealis wrote:
> 
>  Ahhhh, Ok, I thought they were the same. Besides signaling what is 
> the difference from E1 to T1? is there a command channel like the D
> channel for signaling? 

E1 is a much cleaner design compared to T1. While T1 uses some esoteric
means of collecting bits over multiframes in order to do L1 signaling,
E1 is just a Frame of 32 Timeslots (Bytes). Timeslot 0 is used for L1
signaling - no exotic multiframe bit extractions necessary. All other
Timeslots are free for use. If used as a PRI to ISDN, the Timeslot 16
is utilized as the D-Channel. Furthermore, the E1 interface is practically
always a symmetrical G.703 one - just plug the correct RJ45 cable into
the socket on the max, connect to the PRI-NT and you are operative.
It's obviously been designed after some years of observation of T1 and
made better ;)

FMI, see ITU-T Recommendation I.431.

-- 

Kanther-Line: PGP SSH IDEA MD5 GOST RIPE-MD160 3DES RSA FEAL32 RC4

+-o-+--------------------------------------------------------+-o-+
| o |               \\\- Brain Inside -///                   | o |
| o |                   ^^^^^^^^^^^^^^                       | o |
| o | Andre' Beck (ABPSoft) beck@ibh-dd.de XLink PoP Dresden | o |