Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) Switching to Ascend MAX




Can you give information of the remote site equipment
deployed? Is it a Cisco device? It may be configured for HDLC
encapsulation... It's default in Cisco devices...
You may try to fix MRU size to 1500 and turn off link compression
in encap options. If all these do not work, try frame relay encapsulation.

Yasin KAPLAN - INTRAkets
Teknik Mudur - Technical Manager
Tel:+90 (216) 3276930 Ext. 116 Fax: +90 (216) 3276924
http://www.intrakets.com.tr/ kaplan@intrakets.com.tr

> -----Original Message-----
> From: owner-ascend-users@max.bungi.com
> [mailto:owner-ascend-users@max.bungi.com]On Behalf Of Sergio Santos
> Sent: Tuesday, April 20, 1999 8:42 PM
> To: Yasin KAPLAN; ascend-users@bungi.com
> Subject: Re: (ASCEND) Switching to Ascend MAX
>
>
> Hi again,
>
> Our line is (only) 64K.
>
> I have tried this idea, couldn't get it to work, I suspect I may
> be missing
> some other parameter elsewhere, since no activity is seen on the
> serial wan
> port. I think I tried most of the possibilities in the
> Ethernet->Connections
> and on the Serial Wan parameters itself, no dice. At the moment the only
> time I saw some data actual being sent to the Serial Wan port was when I
> configured a Frame Relay connection, of course I couldn't
> establish a valid
> connection, but at least I managed to see some data on the Serial
> Wan status
> window :-|
>
> I recieved also a partial configuration to work with from Ilke TEMIR
> (thanks), it is from another OS, I adapted to my configuration,
> to no avail
> too...
>
> iproute show allways shows the gateway address(remote end ip
> address) trough
> Wanidle0 ...
>
> I forgot to mention, we're using TAOS 7.0.3 here. Maybe I should go "back"
> ...
>
>
>
> Sergio Santos
> Tech Admin,
> Netlandia, Lda
> ssantos@netlandia.pt
> ----- Original Message -----
> From: Yasin KAPLAN <kaplan@intrakets.com.tr>
> To: Sergio Santos <ssantos@netlandia.pt>; <ascend-users@bungi.com>
> Sent: Tuesday, April 20, 1999 1:00 PM
> Subject: RE: (ASCEND) Switching to Ascend MAX
>
>
> >
> > Hi,
> >
> > Just enter a space character in receive password. Because
> > you enable receive-authentication in Ethernet/Answer/PPP options,
> > Max enables receive passwd option in connection profile/encap options.
> > By the way... What is th speed of you leased line connection?
> > if it is different than 64k, let's say 256K, you should define
> it exactly
> > in Swan profile...
> >
> > Yasin KAPLAN - INTRAkets
> > Teknik Mudur - Technical Manager
> > Tel:+90 (216) 3276930 Ext. 116 Fax: +90 (216) 3276924
> > http://www.intrakets.com.tr/ kaplan@intrakets.com.tr
>
>
> ++ Ascend Users Mailing List ++
> To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd:	<http://www.nealis.net/ascend/faq>
>

++ Ascend Users Mailing List ++