Re: (ASCEND) P75 - cause code 34




Thanks for all the help. I've contacted GTE, but its very difficult with
this sporadic problem. Once 34 comes up, I never get to dial out or get
incomming calls. If one channel is already dialed out its fine, it won't
drop until its terminated at my end. But after that, I'm hosed until I
reset the pipeline.

FYI 7.3.0 is sweet. Finally dba works!

At 10:06 AM 4/9/99 -0700, Matt Holdrege wrote:
>At 12:16 AM 4/9/99 -0700, James Johnson wrote:
>>
>>Just recently my pipeline 75 stopped working, siting cause code 34. Upon
>>resetting the unit it works fine, but sometime later (10-20 min) it again
>>stops with cause 34. 
>>
>>According to the Ascend doc, 34 refers to 'No circuit/channel available'.
>>I'm not certain what this means. 
>>
>>This unit is ~1.5 years old, it is a 'new' revision, and the AOS version
>>I'm running is 6.1.19. I've been running with this for about 2-3 months
>>now. I'm Looking forward to trying 7.3.0 with DBA (finally!).
>>
>>Does anyone have a clue what might cause this type of behavior?
>
>I've seen this before and it was the telco. The switch ran out of 64K
>trunks. Sometimes I got through, sometimes I didn't. I tried switching to
>56K and it worked everytime. I called the telco and explained the problem
>and they found that a large bank of circuits had failed.
>

---
;----------------------------------------------- 
    cwd                ; "Do or do not. There is 
    xor     ax,dx      ; no try." Yoda 
    sub     ax,dx      ; 
    mov     Power,ax   ; plexus@seanet.com 
;-----------------------------------------------