RE: (ASCEND) quick question: 4048 & MP



Set the following on both of your MAXen :

Ethernet -> Mod Config -> Stack Options

Stacking Enabled = Yes
Stack Name = whatever
UDP Port = 5151

This works for us.

Sincerely,
Nelson Llabona
	-----Original Message-----
	From:	Joe Pautler [SMTP:pautler@grasshopper.cit.buffalo.edu]
	Sent:	Tuesday, March 17, 1998 12:07 PM
	To:	ascend-users@bungi.com
	Subject:	(ASCEND) quick question: 4048 & MP


	1) Is it possible to do multilink ppp (ISDN) across two seperate
4048's?
	   In other words, first call comes in on one 4048, while second
B
	   channel ends up on 2nd 4048.  Can they handle this via
communicating
	   over the ethernet (assuming they're on the same one)?

	According to the documentation, I believe the answer should be
"yes".

	2) Has anyone done this successfully, or ever heard of anyone
else
	   doing this successfully?

	Any responses would be *greatly* appreciated!  Thanks!

	
________________________________________________________________________
___
	Joe Pautler, E.I.T.                             University at
Buffalo
	CIT/OSS Network Engineering                     224 Computing
Center
	http://www.oss.buffalo.edu/~pautler             (716) 645-3536