Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) Multilinking analog modems



I modified the profile to :

usertst1  Password = "asd", Ascend-PW-Expiration = "Aug 13 2000"
        User-Service = Framed-User,
        Framed-Protocol = MPP,
        Ascend-Assign-IP-Pool = 1,
        Framed-Netmask = 255.255.255.255

usertst2 Password = "asd", Ascend-PW-Expiration = "Aug 13 2000"
        User-Service = Framed-User,
        Framed-Protocol = MPP,
        Ascend-Address = 17.27.10.10,
        Framed-Netmask = 255.255.255.255

but continue to get "Account already in use".

Any other changes I can make on the MAX or RADIUS profile?

Could someone post a generic account that works for Multilinking analog
modems ?

Thanks.

Nelson Llabona
	-----Original Message-----
	...
	At 09:45 1998/03/02 -0500, Llabona, Nelson wrote:
	>Everything works well when the profile is on the MAX, but when
I move
	>this user to >RADIUS,  the second login (I bring up terminal
window after
	dialing) >gives me >and error message from the MAX : "Account
aleady in use"

	>Any other setting required on the MAX or RADIUS profile ?  Any
help is
	>appreciated.

	you may need to do PAP/CHAP login instead of term server.
	or maybe just add 
		User-Service = Framed-User,
		Framed-Protocol = MPP,

	otherwise the config looks OK, but might be a little easier to
debug if you 
	take some of the extra options out, just until the physical like
is working.
	(It does work, I am using one link right now with 4 modems
coming a UNIX box
	acting as a router until a customer's T1 gets installed)

	-Jim H

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>