RE: (ASCEND) Multilinking analog modems
Group,
I followed the settings below on a MAX4004 running 6.0.
Everything works well when the profile is on the MAX, but when I move
this user to
RADIUS, the second login (I bring up terminal window after dialing)
gives me
and error message from the MAX : "Account aleady in use"
My user account looks like this :
testdual Password = "dual", Ascend-PW-Expiration = "Aug 13 2000"
Ascend-PW-Lifetime = 900,
Change-Password = "Yes",
Framed-Protocol = MPP,
Framed-Address = 17.27.10.10,
Ascend-Dialout-Allowed = Dialout-Allowed,
Ascend-Maximum-Channels = 2,
Framed-Netmask = 255.255.255.255,
Framed-Routing = Listen,
Ascend-Idle-Limit = 1200
Any other setting required on the MAX or RADIUS profile ? Any help is
appreciated.
Thanks,
Nelson Llabona
-----Original Message-----
From: Kevin Smith [SMTP:kevin@ascend.com]
Sent: Monday, December 15, 1997 2:42 PM
To: dbotkin@probe.net; steve@i-plus.net
Cc: ascend-users@bungi.com
Subject: Re: (ASCEND) Multilinking analog modems
...
Any since 5.0Ai4 should work...
>which one. I was using Win95 OSR2, one internal 28.8 and one
external
>33.6 (both connected at 26.4). Worked like a champ. You have
to set
>Ether->Answer->Encaps->MPP=Yes, Ether->Answer->PPP Options->Max
Ch
>Count=2, and maybe shared profiles=Yes,
No shared profiles is not needed.
...
Kevin
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com