Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) error in debug mode: SPYDER-6: Initial SA failed



At 10:48 PM 8/20/97 +0200, Thilo Wunderlich wrote:
>While switching to the debug mode on our max 4000 I got the following 
>message:
>SPYDER-6: Initial SA failed
>
>Hehehe, coool he said spyder ...
>
>Any idea what this could be ?

The SPYDER chip is the HDLC resource....apparently slot 6 failed to
initialize, so you would have one less HDLC channel. The whole slot
didn't fail POST, but one channel did. You would probably find it will
initialize just fine next time you reboot the MAX, but if not you
could request an RMA - especially if you get problems with ISDN calls
failing unexpectedly on this box.

The HDLC resource is not used for modem calls, so if you are not doing
any ISDN-data, you could ignore this message (until you do turn to ISDN).


Kevin

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>