Re: (ASCEND) Clock source strategy
At 12:39 08/13/1997 -0500, John Coy wrote:
>how the 'Clock Source' setting should be set? As I understand it,
>the Clock Source = Yes means that the incoming clock from that PRI
>will be used for all other PRIs. What if i want to use a clock
>from my SWB PRIs for ONLY my SWB PRIs and my ACSI clock ONLY for my
>ACSI PRIs?
If you absolutlely must have seperate clocks,
you'll have to use a seperate Max chassis...
They synchronise to a single incoming line only,
and use that clock on ALL lines.
You _shouldn't_ have to do this however unless the telcos
have clock source problems internally, but there's a pretty
fat chance of getting them to fix it just because of your line.
-Jim H
----
Jim Howard Sr Network Engineer Lyceum Internet
jhoward@lyceum.com http://www.lyceum.com/ 404.248.1733
My PGP Public Key: http://www.lyceum.com/~jhoward/pgp-key.txt
Fingerprint: 7E8B E2BA 1314 2535 CB08 CFF9 119B 7CD3 2488 954D