Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Question about Multi IP addr NAT
nelson,
first, the P75 should be configured for "single IP addr" rather than
multi - that might fix your problem
also, are all the computers on the same subnet? that might cause a
problem as well.
the P75 can act as a DHCP server - but I wouldn't recommend it.
hope that helps!
Melissa Meister
"Llabona, Nelson" wrote:
>
> Group,
>
> I have set up the MAX with a connection profile for a pipeline75.
> It connects and can get everywhere, as can the first PC on the hub behind the
> P75.
> When the second PC on the hub powers up, it has no connectivity to the MAX and
> beyond.
>
> First PC continues to work flawlessly while second PC cannot get past the P75.
> Max is running 7.0.4 and P75 is running 6.0.6 load b2.p75.
>
> P75 is configured with NAT:
> ->Routing =yes
> ->Lan = Multi IP addr
>
> And MAX connection profile is set up DHCP Options :
> ->Reply Enables = Yes
> ->Pool Number = 0
> ->Max Leases = 3
>
> Also what DHCP / NAT debug commands can I do on a P75 ???
>
> Sincerely,
> Nelson Llabona
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
--
Melissa
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>