Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Corrected release announcement for Max 6.0.4
Corrections from the previous 6.0.4 release notification:
1) TRs 3014 and 3239 were removed from the email as they were fixed in the
6.0.2 release.
2) Added TRs 3303, 250099, 250219, 250221/2871, and 250270.
*****
Release 6.0.4 for the MAX family has been given to support. This release
contains the following:
TR 2387 Simultaneous calls into a AIM/6 on a Max 4004 were unreliable.
TR 2962 MAX sometimes did not callback (CBCP) to the modem user.
TR 2964 PC client did not get a response from 2 Foreign Agent Max units
when using ATMP with MP stacking.
TR 2965 PHS/PIAFS was slow to disconnect.
TR 2995 MAX possibly running out of memory event; caused Fatal Error 1.
TR 2998 MAX 1800: Nailed/MPP did not work across a serial WAN.
TR 3016 VJ compression caused corrupt TCP header.
TR 3079 File transfer through Zmodem failed over X.25 network.
TR 3092 WANdialout SNMP MIB table did not contain callReferenceNum.
TR 3121 Token card authentication did not work if the Rem Name parameter
on the Pipeline did not match the Sys Name parameter on the MAX.
TR 3125 MAX reset with Fatal Error 2 because of a memory leak.
TR 3126 MAX intermittently refused Telnet sessions to Port 5000.
TR 3155 MAX ignored IGMP version 2 leave message.
TR 3200 Acct Reset Timeout did not work.
TR 3210 FE2 memory Leak in filterEntry pool.
TR 3226 MAX reset with Fatal Error 29 when Realm authentication request
failed.
TR 3266 MAX 6000 reset with Fatal Error 29 with BACP.
TR 3303 Telnet sessions would overwrite each others data.
TR 250099 When ID Auth=Prefer, some connections were refused and some
modems became inaccessible until MAX was reset.
TR 250131 An error occurred in the ISDN signalling sent by a MAX at a call
hangup.
TR 250206 ATMP Home Agent dropped packets from client network when in backup.
TR 250219 MP filters did not work with RADIUS and dynamic IP assignment.
TR 250221/2871 Modem handshake failed when using modem outdial from either
MAXDial or terminal server.
TR 250224 CBCP was not supported on the MAX 200 Plus.
TR 250225 Second IP address sent out as source address.
TR 250257 Silent mode did not work correctly.
TR 250263 With IP Direct, Max did not accept packet size of 1500 with an
MTU of 1500.
TR 250270 RIP version 2 Multicast was missing.
Matt Holdrege http://www.ascend.com matt@ascend.com
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>