Re: (ASCEND) POST Halted on Pipeline
On Tue, Apr 14, 1998 at 01:54:31PM -0400, Mike Neagle wrote:
>
> Pipeline
>
> Power-On Self Test
>
> Halted:
>
> CONFIGURE UNIT!
>
> Anyone ever seen this? Can't get past this initial screen, but can get
> into diagnostics with ESC [ ESC =. Performed an fclear and an nvram, but
> still got this message? It's a Pipe 50 that's olny a few weeks old.
> Should I just get an RMA number?
The P50 has lost its identity. Aka the hash code which tells him
his serial number ;->
Two options:
1) If you like adventurous technical escapades, ask Ascend for the hash
code to restore the serial number and all the hash codes that were
generated/purchased for this unit. They have a database for this.
Then go to debug mode and reinstall the serial number and all options.
Voila - Unit back.
2) If you would better like a new box without an eventual hardware problem
that caused the loss of mind in the first place, yes, get a RMA.
--