Re: (ASCEND) 6.X.X w/ Netopia
>From: Robert Fournerat <robert@netin.com>
>Has anyone else noticed that code (for the Max) above
>6.0.0 doesn't work well with Netopia routers? It seems
>the Max keeps clearing calls. The code seems to work
>consistantly (as far as the problems with Farallons go)
>across 1800's and 6000's.
This is the LQM problem I'm always wining about. Disabling LQM is the
workaround.
>Does Ascend know about this? Is this an Ascend problem?
I have a ticket on it. Ascend has reproduced the problem and has passed it
to Netopia. Netopia has also reproduced it and has given it to their
Engineering folks. This all happened last week.
>A) the problem started with code > 6.0.0 and has not
> been fixed in the 6.1.x set
It started in 2.0.7 (on the TNT, probably 6.0.7 on Maxen), and I've had a
ticket open on it since then.
>B) the Max seems to be the one sending the control
> messages to clear the call
Check your logs. The disconnect codes are based on LQM measurements.
>C) I searched the Ascend web site, and it doesn't
> say anything about this problem
Nobody's perfect...
Peter Lalor Infoasis
plalor@infoasis.com http://www.infoasis.com/