Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Second line usage on ISDN
At 10:43 PM 10/15/98 , Nick Gorham wrote:
>Hi,
>
>Hopefully someone can shed some light on this. I have Pipeline 85's
>comming into a MAX4000, This all works fine, but when I use Radius to
>authenticate, the second line does not come up when the usage increases.
>I expect that I need to set come attributes in the radius profile, I am
>using CLID to authenticate and have the following in the user file
>
>1234X567890 Password = "Ascend-CLID" User-Service = Dialout-Framed-User
> Framed-Protocol = PPP
> User-Name = nick
> Ascend-Maximum-Channels = 2
> Ascend-Target-Util=70
Hmm, methinks that's a good question. The second channel is likely to be
hitting the MAX with a different CLID - and I don't think that it's
settable on the Pipeline (telco would overwrite anything you put in the
calling number, since that's used for billing). I'll check into it, as
I don't recall discussion of this in the RADIUS docs - maybe you need to
set a user profile for both CLID values....?
Kevin Smith (kevin@ascend.com)
Ascend Communications...
...where Network Solutions never end.
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
References: