Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) shared D-Channels on PRI



Regards use of D-channel backup with NFAS:

I saw a couple of postings indicating that loss of the D-channel with NFAS
would bring down all the PRIs in that "group" (pardon possible lack of
correct terminology there)

We have 4 PRIs in our NFAS "group" on each of our MAX 4000s

24th channel on PRI1 is set to NFAS-PRIME
24th channel on PRI4 is set to NFAS-SECOND

This leaves us 94 (24 * 4 - 2)channels for calls. If PRI1 (or its
D-channel) is lost, signalling switches to 24th channel on PRI4.

Works as intended.

Regards Noel



Noel C Johnston	
EMail:		noel@yobbo.com
Telephone:	1-925-675 3050 (Work)	1-925-672 4633 (Home)
Network Consultant	San Francisco Bay Area, California, USA

On Wed, 14 Oct 1998, System Administrator wrote:

> On Wed, 14 Oct 1998, Craig Whitmore wrote:
> 
> > We have 31 channel PRI's (16th channel is D-channel) and 1-15,17-31 as 
> > normal channels(30 + 1 D Channel).. what is NFAS? Can you give an example 
> > of its use? Will it work in New Zealand.? Telecom has to "invent" PR2 so we 
> > could hunt across PRI's (as they had broken NEC (I think) switches) . Clear 
> > in NZ can hunt across PRI's without any problem as they use different 
> > hardware (Don't know what kind).
> > Wed love to do hunting across PRI's on normal PRI's. Telecom said it could 
> > be done. But I was told none of the equipment (cisco, ascend,shiva....) 
> > could do it (Only PABX's etc)
> > 
> > Sig Mode=R2
> > Switch Type=CAS
> > Framing Mode=2DS
> > Complete=end-of-pulsing
> 
> 31 channel PRIs..that's something new to me.
> If we have 2 PRIs here, the relevant config is something like this..
> PRI 1:
> 	Sig Mode=ISDN_NFAS
> 	NFAS ID num=1
> PRI 2:
> 	Sig Mode=ISDN_NFAS
> 	NFAS ID num=2
> 
> I guess the international codes are different, as that I dont have R2
> signaling or a CAS switch type option.
> Have you contacted Ascend at all?
> 
> -Tony
> .-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.
> Anthony J. Biacco                           Network Administrator/Engineer
> admin@intergrafix.net                        Intergrafix Internet Services
> 
>           "The best way to predict the future, is to invent it."
> http://cygnus.ncohafmuta.com                    http://www.intergrafix.net
> .-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.
> 
> > 
> > -----Original Message-----
> > From:	System Administrator [SMTP:admin@intergrafix.net]
> > Sent:	Wednesday, October 14, 1998 3:31 PM
> > To:	Craig Whitmore
> > Cc:	'ascend-users@bungi.com'
> > Subject:	RE: (ASCEND) shared D-Channels on PRI
> > 
> > On Wed, 14 Oct 1998, Craig Whitmore wrote:
> > 
> > > As far as I know you can't under PRI on the max.. telecom here had to use 
> > > PR2 to be able to hunt across PRI's. If its possible I'd like to know. As 
> > > pr2 is a big hassel
> > >
> > 
> > you can share D-channels between PRIs with use of NFAS. give each PRI
> > an NFAS id. Configure your 1 PRI as 23 switched+D and the other as 24
> > switched.
> > Now if you can do it across chassises, i dont know, you would have to try.
> > 
> > -Tony
> > .-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.
> > Anthony J. Biacco                           Network Administrator/Engineer
> > admin@intergrafix.net                        Intergrafix Internet Services
> > 
> >           "The best way to predict the future, is to invent it."
> > http://cygnus.ncohafmuta.com                    http://www.intergrafix.net
> > .-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.
> > 
> > > Thanks
> > > Craig Whitmore
> > > IGRIN Internet
> > >
> > >
> > > -----Original Message-----
> > > From:	Mark Brody [SMTP:mark@opusnet.com]
> > > Sent:	Wednesday, October 14, 1998 10:51 AM
> > > To:	ascend-users@bungi.com
> > > Subject:	(ASCEND) shared D-Channels on PRI
> > >
> > > Question on shared d-channels:
> > >
> > > I have a MAX2024 and a 4048. The 2024 has 1 PRI with a d-channel. I have
> > > added another PRI connecting to the 4048 in the same hunt group. Can the
> > > PRI's share 1 d-channel?
> > >
> > >
> > >
> > > |    M a r k  B r o d y    |
> > > | Opus Creative Group Inc. |
> > > |   Portland, Oregon USA   |
> > > ++ Ascend Users Mailing List ++
> > > To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> > > To get FAQ'd:	<http://www.nealis.net/ascend/faq>
> > >
> > > ++ Ascend Users Mailing List ++
> > > To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
> > > To get FAQ'd:	<http://www.nealis.net/ascend/faq>
> > >
> > 
> 
> 