Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Keeping a p50 connected



Assuming your pipeline is running at least 4.6C, you can go to
Ethernet/Connections/profile_name/Telco Options and set Call Type to
Perm/Switched.  This will make sure that one channel stays connected.

On Fri, 12 Sep 1997 systems@e-z.net wrote:

> 
> I have client with Pipeline 50 that needs to always be connected so that
> can receive inbound traffic.  They are connecting to a Max 4048 on my end.
> I currently can not make outbound ISDN calls due to a telco issue, (We are
> in US Worst territory, what else needs to be said?) so I need to have some
> way of keeping his connection up.
> 
> We've tried tricks like continuously pinging our server via the pipeline
> or having them configure an e-mail client to check for mail every couple
> of minutes, but they are not really happy with these solutions.  I
> promised them a connection that would stay up or reconnect imeadiatly if
> it goes down.  How can I deliver this?

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: