Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Keeping a p50 connected



On the P50, set the idle timers to 0 and the Call Type (in Telco options
for the connection) to Perm/Switched. That tells the P50 to do exactly what
you want. Make sure the Max idle timers for the connection are set to 0 also.

At 09:28 AM 9/12/97 -0700, systems@e-z.net wrote:
>
>I have client with Pipeline 50 that needs to always be connected so that
>can receive inbound traffic.  They are connecting to a Max 4048 on my end.
>I currently can not make outbound ISDN calls due to a telco issue, (We are
>in US Worst territory, what else needs to be said?) so I need to have some
>way of keeping his connection up.
>
>We've tried tricks like continuously pinging our server via the pipeline
>or having them configure an e-mail client to check for mail every couple
>of minutes, but they are not really happy with these solutions.  I
>promised them a connection that would stay up or reconnect imeadiatly if
>it goes down.  How can I deliver this?
>
>------------------------------------------------------
>|                    Lee Nelson                      |
>|                  lnelson@e-z.net                   |
>|            http://www.e-z.net/~lnelson             |
>|----------------------------------------------------|
>|         System Administrator, E-Z.Net Inc.         |
>|                  (360)260-1122                     |
>|          209 NE 120th Ave. Suite B                 |
>|               Vancouver, WA  98684                 |
>------------------------------------------------------
>
>++ Ascend Users Mailing List ++
>To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
>To get FAQ'd:	<http://www.nealis.net/ascend/faq>
>
>
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: