Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

(ASCEND) MAX TNT and channelized E1 for leasead lines



Hi

I have a MAX TNT with software version 1.3Ap5 but I'm having a problem
to configure an E1 like channelized E1 for leased lines.

My configuration is this

name = "LINEAS DEDICADAS"
physical-address* = { shelf-1 slot-1 1 }
line-interface = { yes none 1500 g703 eligible middle-priority e1-no-signaling +
back-to-back = false

admin> list line-interface
enabled = yes
t-online-type = none
t302-timer = 1500
frame-type = g703
clock-source = eligible
clock-priority = middle-priority
signaling-mode = e1-no-signaling
default-call-type = digital
switch-type = switch-cas
front-end-type = short-haul
channel-config = [ { nailed-64-channel 0 "" { any-shelf any-slot 0 } 0 } { nail+
layer3-end = x-side
layer2-end = b-side
nl-value = 64
loop-avoidance = 7
number-complete = end-of-pulsing
group-b-signal = signal-b-6
group-ii-signal = signal-ii-2
answer-delay = 200
caller-id = no-caller-id

channel-config[1] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 0 }
channel-config[2] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 1 }
channel-config[3] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 2 }
channel-config[4] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 9 }
channel-config[5] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 3 }
channel-config[6] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 3 }
channel-config[7] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 4 }
channel-config[8] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 5 }
channel-config[9] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 5 }
channel-config[10] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 8 }
channel-config[11] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 6 }
channel-config[12] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 7 }
channel-config[13] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 11 }
channel-config[14] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 14 }
channel-config[15] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 10 }
channel-config[16] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 10 }
channel-config[17] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 12 }
channel-config[18] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 12 }
channel-config[19] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 13 }
channel-config[20] = { nailed-64-channel 0 "" { any-shelf any-slot 0 } 13 }

I have a MAX 4000 with the same configuration and it works well with the 
channelized E1 and the leased lines.

The difference with the TNT is that I can work with the channel 0 ( channel-config[1] ) and it must be use for signaling in the E1 then maybe the problem is 
the configuration of this channel.

Please could you give some help ?



Regards,

	Enrique


-- 
                                              Atentamente.


*******************************************************************************
Enrique Josue Torres Angeles                eta@rcp.net.pe
Dept. de Proyectos                          Lima - Peru
Dept. de Operaciones                      
Red Cientifica Peruana                      Telefono : 51-1-9544799 
Av. Larco 770 - Miraflores                             51-1-2415689
    3er Piso                                Fax : 51-1-2411320
*******************************************************************************
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>