Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) CACHE-TOKEN+SAFEWORD+RADIUS+Max4000/E1=works?
Hi,
We are trying to get CACHE-TOKEN to work with SAFEWORD & Radius (Ascend or
Secure Computings package of Ascend radius), currently without any luck :-( .
Environment:
------------
Equipment MAX4000/E1 PRI: 5.0Ap16 (ebom.m40)
Pipeline 75: 5.0Ap13 (b.p75)
Workstation SW/HW: SUN Solaris 2.5.1
SUN Sparcstation
SAFEWORD: Version 4.4
Radius: Version 1.16 (plus Ascend extension)
96/10/14. The one packed with the above
SAFEWORD version (whish that they used
proper revision handling etc, not only a
date..)
Problem Description:
--------------------
First, we have used SAFEWORD(4.3) and Radius (late October 1996 from Enigma)
with analog users for over eight months, and it works ok when using PAP-TOKEN
on the Pipeline too. We haven't found anything wrong with our setup but who
knows...
According to our supplier of SAFEWORD, it *should* work if we use
SAFEWORD 4.4 with the Radius packaged on the same CD, but it doesn't :-(.
When running the radius deamon with the "-c" option, I get prompted for
a "PASSCODE" (When in the Pipeline's "set password" mode) 3 times, and
then the connection is terminated with disconnect cause 43 (CHAP
authentication failed). I have set the Pipeline's Send PW and the
radius profile Ascend-Receive-Secret to the same "shared-secret".
---------------------------- Begin included text -----------------------------
falk Password = "SAFEWORD", Ascend-Token-Expiry=22
Ascend-Receive-Secret = "test",
Class = 6570,
User-Service = Framed-User,
Framed-Protocol = MPP,
Framed-Address = 1nn.1nn.nn.250,
Framed-Netmask = 255.255.255.0
---------------------------- Begin included text -----------------------------
---------------------------- Begin included text -----------------------------
Fri Aug 22 18:10:21 1997
NAS-Identifier = 1nn.1nn.nn.16
NAS-Port = 10209
Acct-Status-Type = Stop
Acct-Delay-Time = 0
Acct-Session-Id = "e525465"
Ascend-Disconnect-Cause = 43
Ascend-Connect-Progress = 65
Ascend-Data-Rate = 64000
Ascend-PreSession-Time = 6
Ascend-Pre-Input-Octets = 92
Ascend-Pre-Output-Octets = 104
Ascend-Pre-Input-Packets = 4
Ascend-Pre-Output-Packets = 5
Caller-Id = "nnnnnnnn"
Client-Port-DNIS = "nnnnnnnnn"
---------------------------- End of included text ----------------------------
If we try to use the debug ("-x") option to the radius deamon, then we
will not be prompted for a "PASSCODE". We will immediately be disconnected
with a disconnect cause 43. A debug mode that doesn't behave as "normal-
mode" isn't of much use :-(.
I have heard from another company, that they have the same problems that we
have on their MAX4000/E1, but it works on their MAX200!!
Sounds strange, but I believe anything regards to Ascend Software releases...
Any information, suggestions etc are welcome!
Regards Thomas
--
Thomas Falk Claezon ERICSSON, AXE Research and Development
Phone: +46 8 727 34 12 Box 1505
Fax: +46 8 647 82 76 S-125 25 ALVSJO
Email: falk@uab.ericsson.se SWEDEN
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com