Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: (ASCEND) P=63 error code (+ c=47)
Connect Progress 63 is "Opening IPNCP" (IP Network Control Protocol)
Disconnect 45 is "Recieve Terminate Request"
Disconnect 47 is "No NCP's were open"
This is telling me that you're out of IP addresses, or the users are not
getting assigned an IP address correctly. When this is occuring, check
out what your MAX is doing:
ascend% show pools
Pool# Base Count InUse
1 xxx.yyy.zzz.n 126 44
--
Troy Settle
iPlus Internet Services
It's always a long day... 86400 doesn't fit into a short.
> -----Original Message-----
> From: owner-ascend-users@max.bungi.com
> [mailto:owner-ascend-users@max.bungi.com]On Behalf Of
> sysop@netlink.net.au
> Sent: Monday, July 19, 1999 6:56 PM
> To: ascend-users@bungi.com
> Subject: Re: (ASCEND) P=63 error code (+ c=47)
>
>
> Hi
>
> I have a newly installed MAX 6000 (7.0.3) and am seeing the exact same
> problem and have had to refund clients connection fees as they
> just can not
> get connected, same messages as below, my radius has one differeence it
> shows c=47 not 45 as below.
>
> It has only 1 x 16 56k modem card and 1 pri with 20 lines active so
> resources should not be a problem but the non-connections
> are.. Any ideas
> would be welcome.
>
> Ken
>
> At 12:03 PM 7/19/99 -0500, you wrote:
> >Hello,
> >I have a MAX 6000 running software release code 6.1.24 and it has fully
> populated with 16 port 56K cards and also with 4 T1s. About 3
> weeks ago we
> added the last card and the 4th T1 and ever since then some of the users
> are having a hard time (well, they just don't connect!)
> connecting to this
> particular MAX. They wait a few minutes and then they can
> connect to one
> of our other MAX's (MAX 4048 - same software code). The
> message they are
> getting is either the one about "incompatible set of protocols......" or
> the "the computer you are dialing cannot answer......". In our
> radius log
> we see them trying to connect, but then they are disconnected
> with the P=63
> error code. Below is a sampling of the radius log file. If we
> reset the
> MAX everything is fine for a couple of days, then it starts all
> over again.
> I cannot afford to reset the MAX every couple of days because
> one of these
> days I'm afraid it's not going to come back up. Does the MAX have a
> command that allows you to s!
> >ee the available resources so we can see if the memory is low? Or
> something like that?
> >
> >I would very much appreciate anyr help with this matter as
> soon as possible.
> >Thank you
> >
> >
> >Jul 16 09:54:13 cvtvmax2 ASCEND: call 64 CL 0K u=bednar c=45
> p=63 s=42667
> r=26400
> >Jul 16 09:54:17 cvtvmax2 ASCEND: call 65 CL 0K u=honeydo c=45 p=63
> s=28800 r=28800
> >Jul 16 09:54:56 cvtvmax2 ASCEND: call 68 CL 0K u=honeydo c=45 p=63
> s=28800 r=28800
> >Jul 16 09:54:56 cvtvmax2 ASCEND: call 67 CL 0K u=jjajal c=45
> p=63 s=34000
> r=26400
> >Jul 16 09:55:02 cvtvmax2 ASCEND: call 66 CL 0K u=kisses c=45
> p=63 s=28800
> r=28800
> >Jul 16 09:55:15 cvtvmax2 ASCEND: call 69 CL 0K u=bednar c=45
> p=63 s=42667
> r=26400
>
> >
>
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>