Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Max200 Plus problem
I have a Max200 plus with BRI card and some modems. Software ver +5.0Ap27+
When I try to dial my ISDN connection it gives me the following in syslog...
207.150.60.126: Mon Jan 4 17:28:51: <134>ASCEND: slot 9 port 2,
Outgoing Call, 5226269 915488931
207.150.60.126: Mon Jan 4 17:28:51: <133>ASCEND: call 124 CL 0K
c=2 p=2 915488931
207.150.60.126: Mon Jan 4 17:28:51: <134>ASCEND: slot 9 port 2,
Call Terminated 915488964
And this is from a WANdata for the ISDN session
> WANDATA: open session by profile for paracom
WANDATA: looking for session
profile 0, name paracom, ip 198.247.1.X, ether <none>
startSession paracom
newSession paracom
WANDATA-0: profile 1, 'paracom' assigned
WANDATA-0: >> RouteID 0, state INACTIVE, event OPEN_OUT_REQ
WANDATA-4: attempting to place call to '5226269'
WANDATA-4: << RouteID 34, state CALLING
WANDATA: Call state change, port 10, connected 0, carrier 0
WANDATA-4: WAN state change, route 34
WANDATA-4: >> RouteID 34, state CALLING, event CALL_DISCONNECTED
WANDATA-4: >> RouteID 34, state CALLING, event CLOSE_REQ
WANDATA-4: << RouteID 34, state CLEARING
WANDATA-0: << RouteID 257, state unknown
The only way for the ISDN connection to come up is to reboot the Max. The
connection will work fine until it drops if I try to dial again I get what
is above. Any ideas??? Any help would be appreciated. Thanks to all...
Andy Johnson
Network Engineer
ParaCom Technologies, Inc
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>