Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Dial Back Capability Question
>From: "Christopher E. Nichols (Sys Admin)" <chris@worldramp.net>
> We are going to be setting up a client with a Pipe50 dialing into a Max
>4004. The catch is that, we need the client to initiate the call, then
>have the Max disconnect the user, then call that user back. Has anyone
>done this??? I would really appreciate instructions/settings for this setup.
We do this for lots of people in the reverse: we call their Pipelines from
Maxen, they hang up and call back.
A few details need to be set:
The profiles on both sides need to be Ans/Orig=Both.
The box to get called back has Expect Callback=Yes.
The box to do the callback has Callback=Yes.
If you want to place the initial call free, set:
The box to do the callback has CLID Auth=Prefer (at least).
We do this all with local profiles in the Maxen for simplicity. RADIUS is a
whole other story.
Peter Lalor
Infoasis
plalor@infoasis.com
http://www.infoasis.com/
415-459-7991 x102
415-459-7992 fax
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>