(ASCEND) Pipeline 220 "false" inactive DLCI



Have a problem with Pipeline 220 connected to multiple Pipeline 130s

HQ:
T1 running through Larscom DSU for drop add, 12 data lines split off
v.35 to Pipeline 220.
dlci 100

Site 1:
56K ded into Adtran DSU into Pipeline 130
dlci 101

Site 2:
T1 into Pipeline 130
dlci 102

Site 3:
56K ded into Adtran DSU into Pipeline 130
dlci 103

show fr dlci on the P220 gives:

Site 1		dlci 101		ACTIVE

Site 2		dlci 102		ACTIVE

Site 3		dlci 103		INACTIVE

and on the P130 for dlci 103 gives:

HQ		dlci 100		ACTIVE

works great to Sites 1 & 2
cannot ping to Site 3.

BUT

swapping dlci's for Site 1 & 3, show fr dlci on the P220 gives:

Site 1		dlci 103		ACTIVE

Site 2		dlci 102		ACTIVE

Site 3		dlci 101		INACTIVE

and CAN now ping, telnet, ftp, etc Site 3.

Have totally deleted and re-entered info on the P220 for Site 3, all
parameters are same, P130s same, line types same and DSUs same.  ???????

Would really like to get to all three sites - any ideas???

Thanks,

Brian