Re: (ASCEND) Disconnects on one of my Maxen
On Mon, 31 Aug 1998 19:18:55 -0400, you wrote:
>OK, I must be missing _something_.
>
>Customers are complaining about random disconnects, and I've narrowed it
>down to one of my maxen. The only strange thing I can see is disconnects
>with a Cause Code 240.
>
>Aug 31 19:09:35 max6 ASCEND: call 136 CL 0K u=sparktec c=240 p=65 s=38000
>r=28800 h=209.240.35.81
>Aug 31 19:12:30 max6 ASCEND: call 110 CL 0K u=inkjet c=240 p=65 s=42000
>r=26400 h=209.240.35.104
>
>Before today, the box was running 6.0.0e3 so I tried upgrading it to 6.1.7
>as I was in the middle of doing that anyways. No difference as far as the
>disconnects go.
>
>Ideas? I'm all ears.
>
>
>Rob
Hi Rob,
AFAIK, Disconnect-cause-code 240 means link was brought down because of LQM
(link quality monitor) has decided that link quality was bad.
There is (confirmed in 6.1.3) problem with LQM on multi-channel links,
and you can try to disable it in default answer profile.
Good luck!
Best regards
--