Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Release 5.0Ap51 for the MAX family
5.0Ap51 for the MAX family has been given to support. This release
contains the following corrections:
Corrections:
TR 2950 Could not set Login timeout=0 in Tserv Options to disable
feature.
TR 2964 PC client did not get a response from 2 Foreign Agent Max
units when using ATMP with MP stacking.
TR 3016 VJ compression caused corrupt TCP header.
TR 3066 Stacked MAX units did not refuse a second B channel when
defining Max chan = 1 for MP.
TR 3121 Token card authentication did not work if the Rem Name
parameter on the Pipeline did not match the Sys Name parameter
on the MAX.
TR 3125 MAX reset with Fatal Error 2 because of a memory leak.
TR 3126 MAX intermittently refused Telnet sessions to Port 5000.
TR 3185 Incoming calls were shown as stuck in the “r” state.
TR 3303 Telnet sessions would overwrite each others data.
TR 3337 PPP Dialer caused the MAX unit to reset.
TR 250206 ATMP Home Agent dropped packets from client network when in
backup.
Note: This release contains V1.160T of the Rockwell modem code.