Re: (ASCEND) CRCs increasing rapidly
Hi Leon,
Could be a problem between the pipe and the Telco switch(es). I wouldn't
rule out the Pipeline though. I saw a similiar problem with a Pipe 50
where CRC errors were occuring when a connection was made based upon
callback...a "normal" connection, i.e., no callback was initiated, worked
fine :-/ I believe the software version was 5.1 patch 6 and an update to
patch 9 fixed the problem...the problem may have been only cosmetic;
although, the CRCs where incrementing like crazy, the performance did not
"seem" effected.
--ron
On Tue, 25 Aug 1998, Leon McCalla wrote:
> a customers P50 CRCs are increasing rapidly however the CRCs on the MAX it
> is connected to do not increase. how can this be?
>
> Leon McCalla
>
>