Re: (ASCEND) Radius Servers



Look at Ethernet->Mod Config->Auth and Accounting.  Each has an option
Auth Reset Timeout and Acct Reset Timeout.  This is number of seconds the
max will wait before attempting to switch back to the primary radius
server.  This feature was made available in 6.0.0 I believe.

James

On Sat, 22 Aug 1998, Bao C. Ha wrote:

> 
> I have two Radius servers: primary and secondary.
> 
> When the primary is down, the Max switches to the secondary.  Then,
> when the primary is up, why does it still with the secondary?  How
> do I set it up so that it will always check with the primary one,
> before checking with the secondary?
> 