Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) Disconnection Cause 100
Cause code 100 means the user is timing out on his connection, (thus the
idle timer) either give him a longer idle statment in radius :
Ascend-Idle-Limit = 0, (this will never time out)
or on the box you can change the idle setting under :
ethernet->answer->session op->Idle=xx
Jason Nealis
Director Internet Operations / Network Access
Erols Internet (An RCN Company)
On Fri, 14 Aug 1998, Phillip Grasso wrote:
> Hi,
> Cause
> 100 Invalid information element contents
>
> ASCEND: call 116 CL 0K u=phillip c=100 p=60 s=33600
> r=31200 h=203.35.129.134
> This happens to on 1 box.. Any clues?
> Max is running
> mymax system revision: feik.m40 6.0.8
> system uptime: up 2 days, 13 hours, 16 minutes, 43 seconds
> Install just 3 days ago.
> Running RIP v2, and stacking.
>
> Regards
> Phillip Grasso
>
> -------------------------------------------------
> Phillip Grasso
> One Earth Internet Pty Limited
> Phone +61 2 42269007 Fax: +61 2 42269003
> Email: phillip@1earth.net http://www.1earth.net
> PGP FINGERPRINT 06AA 1A36 2D3C 84E9 BE44 6CC1 8B34 81AB
> 4405 A182
> --------------------------------------------------
> ++ Ascend Users Mailing List ++
> To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
> To get FAQ'd: <http://www.nealis.net/ascend/faq>
>
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
Follow-Ups:
References: