MAX TAOS 6.1.7 Software Release for MAX family is now available. The 6.1.7
release for the MAX family includes the following:
Corrections
TR 1486 Max4000-NFAS Line Quiesce doesn't work.
TR 3227 IP pool addresses aren't being released for ARA.IP connections.
TR 3358 Frame Relay Backup Routing Problem.
TR 3367 MAX resets with FE1.
TR 3474 IP Pool Leak.
TR 3486 After a period time, can no longer telnet to Maxes.
TR 3549 RIP2 Use Multicast Parameter changes when upgrading to 6.1.0
from 5.0ap48.
TR 3557 SNMP resets places a warning 176 before reset
TR 3558 SNMP WAN trap variable not correct.
TR 3567 SNMP Reboot Trap logs misleading information
TR 250301 ATMP not present in Load ebixk.m40, ebixm.m40.
Enhancements:
* Make dialout timer user-configurable
* Add support for monitoring redundant power supplies on the MAX 6000
Known Issue:
* Changing to system software that does not support V.90
If the software version on the MAX supports Rockwell V.90 code, the default
value for the Ethernet > Mod Config > TServ Options > MDM Modulation
parameter is V.90. If you downgrade to a software version on the MAX that
does not support Rockwell V.90 code, you must set the MDM Modulation
paramater to either K56 or V.34. In general, if you downgrade to older
software versions and need to restore a configuration, you must originally
have saved the configuration from a MAX running the older version of code.
Rockwell modem code version:
Series56 Digital Modem Modules support Rockwell 2.084 firmware.
V.34 Digital Modem Modules support version 1.610G19.
Rockwell 2.084 firmware supports V.90, K56flex, K56plus, and all slower,
standard modem speeds.