Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Re: Pipeline 50 Problem
Your pipe has lost its internal serial number, no amount of jumpering/juggling
will avail you. You need to call customer support with the serial number on the
base of the unit. The helpful customer support personel will then generate and
give to you an update command to enter in debug that will restore the pipe's
proper software security number. Upon resetting, the pipe will then successfully
pass the POST.
> From: Eric Taylor <etaylor@visi.com>
> Date: Wed, 12 Aug 1998 14:02:08 -0500
> Subject: (ASCEND) Pipeline 50 Problem
>
> I have a problem with a Pipeline 50 that I just came across today. I am
> getting an error that says the following at power up: Pipeline Power-On
> Self Test Halted: CONFIGURE UNIT!. Now I am aware of the trick of
> popping in a jumper to get into ck mode and uploading the system
> software that route. However, this has not helped. If any of you have
> any feedback I would appreciate it.
>
> Thanks,
> Eric
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>