Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Pipeline CRC Errors
We have the same problem with our P130 that goes to one of our pops (full
point-to-point T1). About every month we found that we had to reboot the
P130 because of CRC errors. Today we had that same problem and a reboot
did not solve the problem. We had to unplug the P130 and restart it to
solve the problem. It's an older P130 with a 4.6Ci18 code. I sent an
email message to ascend support about asking if an upgrade software will
solve this problem. But it sounds like you have upgraded the software and
it still has this problem. May be time to get another router.
Thanks,
Ken Rea
> From: Susie Ward <sward@voltage.net>
> Date: Fri, 01 Jan 1999 09:04:09 -0600
> Subject: (ASCEND) Pipeline CRC Errors
>
> I've had my Pipeline 130 for well over a year. It ran a dedicated ISDN for
> a little over a year with no problems. A few months ago I upgraded to 256k
> FR and I've started getting these CRC errors and collisions. I've had the
> telco test the lines a few times and they can never find any problems on
> their end.
>
> I just upgraded to 6.1.5 to see if that fixed anything, so far it doesn't
> seem to have helped. I was hoping that someone could give me some ideas
> what to try next.
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>