Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: (ASCEND) CRC Help?



Yes, the problem does move with the lines.  The Max has also begun
'locking up' about once every 18-24 hours since upgrading to
6.1.3 of b.m2, requiring the power to be cycled.  Not good..

-----Original Message-----
From: Leon McCalla [mailto:ascend@caribbeanlink.com]
Sent: Saturday, August 01, 1998 9:58 PM
To: L. Reynolds LeVally; ascend-users@max.bungi.com
Subject: Re: (ASCEND) CRC Help?


swap the lines to see if the problem moves. if it does, swap the customers
at the remote ends of the line to see if the problem moves again.

keep us posted with the results

Leon McCalla

-----Original Message-----
>I'm seeing an average of 1500 CRCs/hour on one of our two BRIs (the
>other line is clean);
>
>How bad is this?
>How do I troubleshoot the problem?
>

 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: