Re: (ASCEND) Can a p130 handle a full t1?



At 12:33 PM 9/24/97 -0700, Josh Beck wrote:
>> the issue should be looked at.  FR works great, just don't try to connect
>> multiple PVC's.
>
>	Multiple PVCs on a P130 works just fine... we have a customer with
>two P130's and a Cisco connected in a triangle, two PVCs on each of the
>P130's and a ton of PVCs on the Cisco. A bit of static routing, interface
>based addressing and everything worked perfectly. It's actually kind of
>handy because when a circuit goes down (happens all the time thanks to
>PacBell) we can look at both PVCs and see if it is the DS1 that is down or
>just one of the PVCs. 

I have exactly the same setup. Works fine.
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>