Re: (ASCEND) Max 4000 & P50



Andre Beck wrote:
> 
> On Tue, Sep 23, 1997 at 02:55:50PM -0700, Peter Tran wrote:
> >
> > Do the Max 4000 & the Pipeline P50 support 128 kb leased line?
> 
> Sort of. The problem is at the P50.
> 
> 1) The P50 has no Leased/Leased setting until now. Current status is that
>    the feature may appear in Oct97. We need it strong, so we are quite
>    on the edge here ;)
>    This makes use of the obvious MPP bundling impossible.

We also need it !!!! I canīt see the problem why it isn#t possible. The
feature works on all the MAX-boxes as far as i know.

> 
> 2) SuperDig128
>    The P50 has SuperDig128, a very mystical feature that is "only available
>    in Japan". Of cause this is Zen. Actually SuperDig128 seems to be a
>    straight B1B2B1B2 low level bundling in the S0 frames. This makes it
>    very easy to handle and performant but also very sensitive to any kind
>    of asynchronity in the two B channels of such leased lines. Result:
>    a) It works perfectly with our selfmade lines in lab
>    b) It doesn't work with the lines provided by our telco (German Telekom).

I played around with this feature for some hours -----> no success
We hope that ascend will do it in October

-- 
------------------------------------------