On Thu, Sep 18, 1997 at 03:27:46AM -0400, Troy Settle wrote:
> Hey all, I probably missed this somewhere else, but can anyone tell me if I
> can use the v.35 port on my 4004 to connect a T1 loop to the v.35 on a 4048
> at a remote location?

Should work without problems, with the correct external TA device. We are
doing this here with E1, I see no reason why T1 would be any different in
that.

> Or, could I possibly use a T1 port on the 4004 on one end, and the v.35 on
> the other end?

Should work as well.

We've tested:

MAX E1 <---> MAX E1
MAX E1 <---> Primus TA <-> MAX Serial WAN
MAX E1 <---> Primus TA <-> Pipe130 V.35 (!)

All other combinations will probably work as well. Drawback with using an
E1 this way is you instantly lose 31 HDLC channels.

BTW, the serial ports are not only V.35 but X.21 as well. Especially (and to
my own big surprise) even the Pipe130/V.35 works against a Primus TA with
X.21 cabling, meaning the Pipe130 serial port is the same as on a Max and
not V.35 only as mentioned in the "docs". The only problem is it really
won't speak more than 1.5 Mbps.

BTW^2, are the MX-SL-2PMHP cards adding "serial host ports" or "serial wan
ports" ? If they add host ports, what are they good for and is there any
chance to turn them into/use them as serial wan ports ?

TIA,
Andre.
-- 

Kanther-Line: PGP SSH IDEA MD5 GOST RIPE-MD160 3DES RSA FEAL32 RC4

+-o-+--------------------------------------------------------+-o-+
| o |               \\\- Brain Inside -///                   | o |
| o |                   ^^^^^^^^^^^^^^                       | o |
| o | Andre' Beck (ABPSoft) beck@ibh-dd.de XLink PoP Dresden | o |
+-o-+--------------------------------------------------------+-o-+
++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


Follow-Ups: References: