Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
(ASCEND) Dynamic BW not working on P75
Hi listers. In a previous post I asked if anyone was having problems
with dynamic bandwidth allocation on their P75 running 5.1A Today,
Ascend confirmed my suspicion and opened a bug report. Below is a copy
of my email exchange.
> I have run into one problem however. I am using MP+ to access my ISP
> which has MAX equipment on their end. Prior to installing 5.1A, the
> dynamic bandwidth allocation algorithm worked as advertised. However,
> since installing 5.1A, the P75 no longer waits AddPers seconds before
> adding the second channel. Immediately upon reaching ALU >= TargetUtil,
> the P75 brings up the second channel. Can you confirm whether this is a
> known problem in this release?
>
> >>>I have done some testing with the Dynamic Bandwidth Allocation on 5.1A.
> Based on this testing, I have opened a TR (bug report) with Engineering.
> We will contact you when this TR is fixed. Basically, the Pipeline is not
> now controlling the adding of channels. If the MAX is changed to match
> your desired settings, the 2nd channel will be added based on what the MAX
> sees for ALU. This would be the workaround until this TR is fixed. You
> can call/mail on the ticket number above to check on the status of this TR.
--
Mark Hilbush
Everything should be made as simple as possible, but not simpler.
-- Albert Einstein
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>