Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) P75: Is AddPers being ignored in 5.1A?



At 09:50 09/07/1997 -0400, Mark Hilbush wrote:
>since installing 5.1A, the P75 no longer waits AddPers seconds before
>adding the second channel.  Immediately upon reaching ALU >= TargetUtil,

>My settings are:
>EncapsOptions->SecHistory=15
>EncapsOptions->AddPers=15
>EncapsOptions->SubPers=60
>EncapsOptions->TargetUtil=60

maybe have something to do with SecHistory=AddPers?
or possibly DBA Monitor?

on my setup, 
>EncapsOptions->DBA Monitor=Transmit-Recv
>EncapsOptions->SecHistory=60
>EncapsOptions->AddPers=30
>EncapsOptions->SubPers=30
>EncapsOptions->TargetUtil=25

does the right thing and waits 30 seconds, however when

>EncapsOptions->DBA Monitor=Transmit

it brought up the second channel way before 30 seconds,
but I didn't dig deeply into whether it was the pipeline
or the remote MAX that asked for the increase.
(pipeline dialed -> max)

-Jim H
----
Jim Howard             Sr Network Engineer        Lyceum Internet
jhoward@lyceum.com     http://www.lyceum.com/     404.248.1733     

My PGP Public Key: http://www.lyceum.com/~jhoward/pgp-key.txt
Fingerprint: 7E8B E2BA 1314 2535 CB08  CFF9 119B 7CD3 2488 954D

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com